K25A Track Feeder Cables to NF F 55-625
Application
K25A Track Feeder Cables are designed for fixed power or lighting installations in rail transport.
Standards
NF F 55-625
UNE 21123
Construction

Conductors
Stranded bare copper conductor, 1.5mm² to IEC 60228 class 2.
Insulation
XLPE.
Filler & Inner Covering
LSZH.
Armour
Galvanized steel tapes.
Outer Sheath
LSZH, antitermite, coloured black.
Electrical Characteristics at 20℃
| Nominal Conductor Cross Section | mm² | 1.5 |
|---|---|---|
| Maximum DC Conductor Resistance | Ω/km | 12.2 |
| Minimum Insulation resistance @500VDC | MΩ.km | 1500 |
| Voltage Rating | KV | 0.6/1(0.45/0.75 optional) |
Mechanical and Thermal Properties
Minimum Bending Radius: 10×OD
Temperature Range: -20℃ to +60℃ (during operation);
-10℃ to +60℃ (during installation)
Core Identification
Colours coding: Black, Light blue, Brown, Green/Yellow, Black
Dimensions And Weight
| Cable Code | No. of cores& Nominal
Conductor Cross Sectional Area No.×mm² |
No. & Nominal
Diameter of Strands No/mm |
Minimum
Overall Diameter mm |
Maximum
Overall Diameter mm |
Nominal
Weight kg/km |
|---|---|---|---|---|---|
| RF/K25A-RZ1F3Z1-U(AS)-0.6/1KV-2G1.5 | 2 x 1.5 | 7/0.53 | 8.0 | 12.0 | 100 |
| RF/K25A-RZ1F3Z1-U(AS)-0.6/1KV-4G1.5 | 4 x 1.5 | 7/0.53 | 12.5 | 14.5 | 300 |
| RF/K25A-RZ1F3Z1-U(AS)-0.6/1KV-12G1.5 | 12 x 1.5 | 7/0.53 | 18.0 | 20.0 | 590 |
| RF/K25A-RZ1F3Z1-U(AS)-0.6/1KV-21G1.5 | 21 x 1.5 | 7/0.53 | 22.0 | 24.0 | 830 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information